HAIEN ENERGYCompany News

Company's First Flexibility-Retrofit EPC Project and First Intermediate-Control-Valve Participation Project Pass Testing

The 135 MW steam-turbine flexibility retrofit for Xinjiang Huayi Jinlong Thermal Power Co., Ltd. was the company's first EPC project for a thermal-power flexibility retrofit. The company was responsible for equipment design, manufacturing, installation, and commissioning.

The project passed testing on the first attempt on November 7, 2024, breaking the original heat-to-power relationship of the cogeneration unit, achieving zero output from the low-pressure cylinder, and maximizing heat-supply capability.

The intermediate-control-valve participation test service for the 350 MW steam turbine high- and low-pressure bypass and heating-drain retrofit at Xinjiang Huadian Hami Thermal Power Co., Ltd. was the company's first technical-service project for intermediate-control-valve participation in combined high- and low-pressure bypass heating.

The company prepared the test plan, provided on-site commissioning guidance, and summarized the test report. The project passed testing on December 4, 2024. With intermediate-control-valve participation, turbine electrical load fell to 40%, heat supply reached 523 t/h, design requirements were met, and all turbine monitoring data were normal.

Against the background of the dual-carbon goals, thermal-power units must undertake more peak-shaving while meeting industrial and residential heating needs and supporting renewable-energy consumption. National policies therefore encourage thermal-power flexibility and deep peak-shaving retrofits.

Steam-turbine flexibility retrofit is also known as extraction-backpressure conversion, cylinder-cutting retrofit, or low-pressure-cylinder zero-output retrofit. During operation, all steam admission to the low-pressure cylinder is cut off and only a small amount of cooling steam is admitted, producing zero output from the low-pressure cylinder.

In cylinder-cutting mode, high-quality steam generates power through the high- and intermediate-pressure cylinders, while intermediate-pressure exhaust steam enters the heating network. This eliminates cold-end losses, enables cascading energy use, lowers electrical output while maintaining the heating area, and improves flexible adjustment of heat and power loads as well as heating and peak-shaving capability.

Figure 1. Principle of low-pressure-cylinder steam-admission cut-off

Article image 1 of 5

Figure 2. Jinlong unit operating screen after cylinder cutting

Article image 2 of 5

Combined high- and low-pressure bypass heating is used when cylinder cutting alone cannot meet heating demand. High-parameter steam is desuperheated and depressurized through the turbine bypasses for external heat supply.

By adjusting bypass steam flow, steam entering the three turbine cylinders is reduced, heat-supply capability at low load is increased, and the deep peak-shaving range is expanded. Intermediate-control-valve participation adjusts intermediate-pressure control-valve opening to maintain high-pressure exhaust pressure at the design value for the corresponding load, ensuring safe turbine operation during combined bypass heating.

Figure 3. Principle of combined high- and low-pressure bypass heating

Article image 3 of 5

Figure 4. Hami combined-bypass heating operating screen

Article image 4 of 5

END

Text: Yang Zengchao

Editor: Zhou Yan

Initial review: Huang Jipeng

Final review: Yu Gang

Contact: Marketing Center, Manager Liu: 0838-2593270 / 15182649747